Part Number: MSP430FR2633
Hi Experts,
Our customer has develop trial thin system board (7 Bottoms / self-capacitance ) with MSP430DR2633 and customer is verifying Immunity tests now. Currently customer observed that this board is sometime doing erroneous detection during Electrical Fast Transient t Immunity (IEC 61000-4-4).
Regarding Hardware, customer is not able to change anything due to some reason. Therefore, customer is trying to do tuning some parameter with Captivate Design Center at this time. Customer performs Immunity test while changing the Conversion-Count, Conversion-Gain and Touch threshold, however, customer is not able to find good parameters yet. Also, customer still observed misdetection after Enabling “Noise Immunity” on Noise Immunity Tag.
Now, customer is verifying “Frequency Divider” at this time. As you know, Captivate design center has many setting parameters. Therefore, customer would like to know parameters which affects Fast Transient t Immunity test Could you elaborate it, please?
During doing t Immunity tests, Customer was not able to connect Debugger(CAPTIVATE-PGMR). Therefore, It is really appreciated if you are able to do quick comments on this.
Since I noticed the following “Tuning Check List” , I’ll share it, at first.
Best regards,
Miyazaki