Part Number: MSP430FR5043
Tool/software:
Team,
In older MSP430 F5xxx Generation (like MSP430F5658) there was two different driver strength available for digital IOs (Full Drive strength/reduced drive strength):
See section 8.11 of F5xxx datasheet: https://www.ti.com/lit/pdf/SLAS700
In MSP430 FR5043 it seems that there is one single driver strength (that seem to correspond to the reduced drive strength of the F5xxx) :
See Section 8.13.5.2 of the FR5043 datasheet: https://www.ti.com/document-viewer/MSP430FR5043/datasheet#GUID-EB46F037-4CE0-4EF7-BDEE-C17725CC03D8/TITLE-SLASEF5T46804113219
-Can you please confirm if the driver strength is fixed as per the datasheet?
-Or is there a way to configure it (like on F5xxx)?
Thanks in advance,
Anthony